====== Grandstream DP750 DECT Base with DP720 Handsets ====== User Guide: http://www.grandstream.com/sites/default/files/Resources/DP750_DP720_User_Guide.pdf ===== Register a Handset ===== ==== DP750 Base Station ==== Press and hold the ''Radio/Page'' button for 7 seconds until the Radio icon starts blinking Or in the web UI, press Subscribe icon. ==== DP720 Handset ==== Press ''Subscribe'' softkey, if available on the main screen, or access **Menu -> Registration -> Register** while the DP750 Radio icon is blinking :!: The ''Subscribe'' softkey appears only if DP720 is not registered to any DP750 base station. ===== Battery Replacement ===== :!: See the User Guide for battery information. :!: Do **not** use standard alkaline batteries. A good option: ^Panasonic |BK-4MCCA8BA |eneloop AAA 2100 Cycle Ni-MH Rechargeable Batteries | ===== Firmware Upgrades ===== :!: You should probably **place all the handsets in their charging cradles** before starting the update. - **Log in to your DP750 base station** using the web interface * The default credentials are ''admin / admin'' - **Maintenance** -> **Firmware Upgrade** -> - **Firmware Server Path** -> ''firmware.grandstream.com'' - **Handset Firmware Automatic Upgrade** -> ''Yes'' - Click ''Save and Apply'' - **Reboot** the base station After the base reboots and upgrades to the latest version, the handsets will commence updating one at a time. :!: Be patient!