====== Cisco/Linksys SPA3102 ATA Connection Notes ======
FIXME This page is copied from another and is incorrect and incomplete.
See also: **[[voice:ata:spa2100|Linksys/Sipura SPA-2100 ATA Connection Notes]]**
See also: **[[voice:ata:grandstream_ata|Grandstream Analog Gateways and ATAs]]**
See also: **[[voice:pbx:freepbx:freepbx_ata|FreePBX with Analog Telephony Adapters]]**
===== Seven Digit Dialing =====
{{ :voice:ata:spa3102.jpg?300|SPA3102}}
If you use a SIP trunk provider that requires 10 digits, modify the Dialplan in the Line1 (or Line2) settings by inserting ''<:520>'' to the 7-digit section:
|<:520>[2-9]xxxxxx|
:!: In this example, we need ''520'' (our local area code) added to dial 7-digit calls.
(*xx|[3469]11|0|00|<:520>[2-9]xxxxxx|1xxx[2-9]xxxxxxS0|xxxxxxxxxxxx.)
===== Audio Quality and CODEC =====
For maximum bandwidth savings, use ''g.729a''. Otherwise, choose (the default) ''g.711u'' (uncompressed) for best audio quality. It's roughly 24Kbps vs. 92Kbps.
:!: Be sure to set the ''RTP Packet Size'' to ''0.020'' on the SIP tab.
===== Paging =====
In our limited experience, paging amplifiers are usually connected to an FXO port of a PBX. **The SPA3102 includes an FXO port**.
http://wiki.freepbx.org/display/FOP/Using+an+SPA3102+FXO+Port+to+connect+with+Valcom+Paging+units
==== Overview ====
- Configure a SIP Trunk and Outbound Route in FreePBX
- Configure the SPA3102
- Determine "Line-In-Use Voltage" of the FXO port and adjust it to match
- Otherwise inbound calls in will result in a busy signal (SIP response 503 "Service Unavailable")
===== Enable the Web Interface on WAN =====
{{ :voice:ata:spa3102_connections.jpg?300|SPA3102 Connections}}
Whereas the **WAN interface is used to connect to the SIP trunk provider**, the **web management of the SPA3102 is only available on the LAN interface** of the unit. If your SPA3102 is completely behind another firewall, you will find it more convenient to enable the web management on the WAN interface.
:!: Do **not** make the web interface accessible if your WAN interface is internet-accessible.
The default settings will leave the SPA3102 in an un-managable state if you only connect the WAN port to your internal network...a common configuration. One would have to connect a portable PC to the LAN interface to administer the unit.
These steps will enable the web interface on the WAN port:
- Plug in an analog phone or 'butt set' into the Phone port
- Dial ''****'' (four asterisks) for the (audible) main menu
- Dial ''110#'' for the IP submenu
- Dial ''7932#'' then
- Dial ''1#'' to confirm