====== Grandstream Analog Gateways and ATAs ====== ===== GXW-400x ===== * 4 or 8 Ports **FXS** * Router * 2x 10/100 Ethernet ===== GXW-410x ===== http://www.freepbx.org/forum/freepbx/tips-and-tricks/how-to-grandstream-gxw-4104-setup * 4 or 8 Ports **FXO** * 2x 10/100 Ethernet ===== HT70x ATA ===== ^ Model ^ Note ^ | HT502 | 2 FXS Ports, Router | | HT503 | 1 FXS, 1FXO, Router | | HT701 | 1 FXS Port | | HT702 | 2 FXS Ports | | HT704 | 4 FXS Ports | * DHCP client by default * Factory reset * Press reset button for 7 seconds * Voice menu * Connect analog phone or butt set to FXS port * Dial **three asterisks** for voice menu * Then dial ''02'' to hear current IP address * Default password * ''admin'' ==== Configuration ==== :!: Start from **factory default** settings and use a **web browser** to access the current IP address. === Basic Settings === * Time Zone === FXS Settings === * **Active** = ''yes'' * **Primary SIP Server** = ''inbound23.vitelity.net'' * **Outbound Proxy** = ''outbound.vitelity.net'' * **SIP User ID** = '''' * **Authenticate ID** = '''' * **Authenticate Password** = '''' * **Apply** and **Reboot** == Dial Plan == Factory default: { x+ | *x+ | *xx*x+ } 7 and 11 digit dialing, plus emergency and international: {<=1520>[2-9]xxxxxx|1[2-9]xx[2-9]xxxxxx|[89]11|011x+}